QA Medivisor Agent (CAL-016)

Calibration and QA testing software and Calibration sensor


QA Medivisor Agent - QA software solution

Medical monitors are required to perform quality control in compliance with the standards (guidelines) of each country. Proper quality control keeps well condition display for long.

Without proper quality control

With proper quality control

 

Achieve quality control for individual monitors

QA Medivisor Agent can efficiently perform quality maintenance work such as calibration, acceptance test, constancy test, asset management, etc. for each monitor.

It is provided as a calibration kit CAL-016 that includes an external calibration sensor.

User-friendly interface

Quality Assurance Software QA Medivisor Agent has simple icon menu for easy access to desired functions.

Individual functions can be operated intuitively and monitor inspection and quality control can be easily performed without spending time learning the operation.

Quality control with easy navigation

Acceptance Test

 

Calibration

Quality maintenance work complied with standards and guidelines

By complying with the guidelines for quality control in each country such as AAPM TG18, DIN 6868-157, JESRA X-0093, stable quality maintenance work can be performed efficiently.

The results and history of quality control and calibration can be displayed on the screen as well as reported (PDF).

High-precision calibration function compliant with DICOM Part14

The calibration function realizes the monitor keeping grayscale characteristics compliant with the grayscale standard display function (GSDF) specified in DICOM Part 14. It can be reproduced with high accuracy and no longer affected by aging.

Supporting planned maintenance

You can set the date and time when to perform calibration and QA test. Notified by pop-up at the set date and time, you can prevent forgetting maintenance, promote regular maintenance, and make quality control a habit. The date and time can be set in various ways according to the action items, such as when logging on or on a specified date, and the hospital can perform accurate quality control operations without interfering with the normal operations of the hospital.

Compliance with standards / guidelines

International standards

IEC 62563-2: Medical electrical equipment - Medical image display systems - Part 2: Acceptance and constancy tests for medical image displays

 

United States of America

AAPM TG18: American Association of Physicists in Medicine

NY State PDM: Guide for Radiation Safety/Quality Assurance Programs: Primary Diagnostic Monitors by New York State

 

Germany

DIN 6868-157: Deutsches Institut für Normung

 

Japan

JESRA X-0093*B-2017: Quality Assurance (QA) Guideline for Medical Imaging Display Systems: Japan Medical Imaging and Radiological Systems Industries Association

Digital Mammography Quality Control Manual: The Japan Central Organization on Quality Assurance of Breast Cancer Screening 

 

Austria

ONR195240-20: Image quality assurance in diagnostic X-ray departments - Part 20: Acceptance testing and constancy testing on image display devices

 

  • Calibration Kit for all JVC Displays
  • Includes Calibration Sensor
Technical Specifications
Technical Specifications
Compatible Operating Systems
Compatible Operating Systems
Windows 11, Windows 10 64/32bit
Compatible Monitors
All JVC Medical monitors
Yes, except for CV932PJ
Supported Languages
English, Japanese, German, Spanish, Italian, French
Maximum of connected monitors
6 units
Others
Package Contents
CD-ROM (QA Medivisor Agent), Calibrator (Calibrator-T4)