Healthcare

MS55I2 PLUS

MENU

5MP Monochrome LCD Monitor

MS55i2 plus Archived

5MP 21.3" Monochrome Monitor / Breast imaging


  • Tomosynthesis
  • Mammography
  • Thorax (CR)
  • CT/MR

Improved Diagnostic Visibility

  • The MS55i2 plus comes with 1,000 cd/m2 calibration to make it the best solution for breast tomosynthesis imaging. The brighter screen dramatically increases the number of perceptual grayscale steps to improve visibility of microcalcifications, tumors and structures. Mammography diagnostic reading will be much more efficient.

    ISD - Because details matter

    The JVC patented ISD technology gives you a whole new view. ISD increases resolution by three for a precision you never saw on a display before. This enables up to 15 Million Pixels on a single display.
     

    Independent Subpixel Driving

    A monochrome display has a large number of pixel elements and each pixel element consists of three sub-pixels, which are driven as one pixel in conventional monochrome displays. Newly developed technology, Independent Sub-pixel Drive (ISD) composed of a display that comes with the ISD algorithm and special viewer software enables each sub pixel to be driven independently, and consequently MS55i2 plus provides superior, lossless image reproduction.

    Image beside shows mechanism of resolution enhancement by the ISD and comparison of captured images on a conventional display and a display with ISD technology. By the ISD function, the image is depicted more accurately.

    *ISD needs to be activated by activation CDROM which needs to be purchased seperately

    Brightness Uniformity Correction

  • Uniformity equalizer is built in to achieve highly accurate luminance uniformity across the screen. With the optional calibration kit this calibration can be refreshed.

    Advanced Front Sensor System

    Sentinel II consists of a luminance sensor and a luminance control circuit. The luminance sensor in integrated into the front bezel, directly against the screen, and constantly monitors and accurately stabilizes luminance on the screen surface by sending feedback instantaneously to the control circuit. Result is a very stable image quality with a day by day diagnostic confidence.

    Front Sensor and PM Medivisor - The perfect match

    Together with PM Medivisor you can get all additional benefits from the sensor system by enabling remote calibration and remote conformance testing.

    Remote management at its best

    With the JVC Software solutions and remote management you become the QA expert. The QA Medivisor Agent suite makes calibration and testing as simple as possible. With PM Medivisor and PM Medivisor cloud you unleash the full remote functionality. All remote features are so advanced that you don't even get noticed. The integrated front sensor checks constantly the image quality. This data is send to the server and available by a web interface you can access from any workstation. Calibration tasks can be scheduled and executed remotely with the front sensor. This cuts maintenance time and effort. The email notice function sends messages in case of too high ambient light, changed configuration or trouble.

    • Uniformity correction
    • DICOM calibration
    • 5 Megapixel - 2000 cd/m² - 1400 :1 contrast
    • Remote calibration and management
    Technical Specifications
    Technical Specifications
    Display Specs
    Display size
    21.3“ (54.1 cm)
    Display Area
    337.92 mm x 422.4 mm
    LED Backlight
    Yes
    Resolution (native)
    2048 x 2560 (5 Megapixel)
    Resolution (ISD)
    2048 x 7680(15 Mega-Sub-Pixel)
    Pixel pitch
    0.165 mm x 0.165 mm
    Pixel pitch (ISD)
    0.165 mm x 0.055 mm
    Number of greyscales via DVI
    2048
    Number of greyscales via DisplayPort
    2048
    LUT (Look Up Table)
    16 Bit per RGB Channel
    Maximum brightness
    2000 cd/m²
    Factory Calibration
    500 cd/m² / 1000 cd/m²
    Contrast ratio
    1400 :1
    Viewing angle
    h: 178° / v: 178°
    Protection filter
    Yes, (only filter model)
    AR Coating
    Yes, (only AR model)
    Integrated Sensors
    Ambient light sensor
    Yes
    Front Sensor
    Yes
    Display Features
    Calibration Feature
    Yes
    Brightness Uniformity Correction
    Yes
    Remote Calibration
    Yes
    ISD Technology
    Yes
    Built-In DICOM Conformance Test
    Yes
    Display Input Output
    DVI Input
    Yes, (Dual Link)
    DisplayPort Input
    Yes, Ver. 1.1
    USB Interface
    USB Interface
    Yes, USB 2.0
    USB Hub
    Yes
    USB Connections
    1x Up / 2x Down
    Display Applications
    Tomosynthesis
    Yes
    Mammography
    Yes
    Thorax (CR)
    Yes
    CT/MR
    Yes
    General Display
    Power
    100V ~ 240V (±10%) 50/60Hz
    Integrated power supply
    Yes
    Power consumption
    75W
    Height adjustment
    Yes
    Portrait function
    Yes
    VESA mount
    Yes, (100mm)
    Dimensions Landscape
    Net: W: 474.5 x H: 486.1 / 547.6 x D: 220 mm
    Dimensions Portrait
    Net: W: 390 x H: 525.2 / 586.7 x D: 220 mm
    Weight
    approx. 13kg